Home
About Us
Product
Events
Company
Services
Courses
Blog
Warranty
0
Sign in
Contact Us
Previous
Next
Show categories
Categories
All Products
PCR Max
Milwaukee Instrument
Apera Instrument
LGC Biosearch
Cole Palmer
DLAB
Water.Id
Euromex
Idexx Tecta
Products
Apera Instrument
Public Pricelist
Public Pricelist
Sort By:
Price - High to Low
Price - Low to High
Price - High to Low
Newest arrivals
Name
APERA, AMCO Polymer Standard Calibration Solution Set for Apera Instruments TN400 Turbidity Meter
Rp
1
Rp
1
1.0
IDR
APERA, 80z pH Calibration Buffer Solution Kit (pH 4.00, 7.00 & 10.01), Plus 40z Storage Solution for pH/ORP Electodes
Rp
1
Rp
1
1.0
IDR
APERA, Portable White Light Turbidity Meter
Rp
1
Rp
1
1.0
IDR
APERA, Benchtop pH/Conductivity Meter Kit with TestBench
Rp
1
Rp
1
1.0
IDR
Basic Features APERA, Benchtop pH/Conductivity Meter Kit with TestBench
Comes with Apera TestBench that incorporates a flexible electrode holder, an intelligent stirrer, and buffer organizers altogether, streamlining the process of pH measurement and calibration.
Simultaneous measurement of pH and conductivity/TDS/salinity
Intuitive operating navigation with natural language and graphics
Multi-language operating system (English, German, Spanish, Mandarin)
Automatic calibration, automatic temperature compensation, self-diagnosis.
Manual data logger with 200 groups of storage
pH Features
Comes with the Swiss LabSen® 211 pH combination electrode and the MP500 temperature probe, achieving highly accurate measurements in the fastest manner
1 to 3 points automatic calibration with calibration instruction and self-diagnosis
Automatically recognizes pH standard solution (1.68, 4.00, 7.00, 10.01, 12.45). 3 series buffer standards for selection: USA, NIST, China series, as well as user-customized standards.
Automatically display electrode slope.
Standard BNC pH connector, RCA connector for a temperature probe, NTC 30KΩ thermistor
Conductivity Features
The 2401T-F glass conductivity/temp. electrode designed for research-level conductivity measurement from 0 to 200mS/cm at ±1% F.S
accuracy
1 to 4 points automatic calibration with calibration instruction and self-diagnosis
Automatically recognizes conductivity standard solution (84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm).
Standard BNC conductivity connector, RCA connector for a temperature probe, NTC 30KΩ thermistor
APERA, Benchtop Conductivity Meter Kit with TestBench
Rp
1
Rp
1
1.0
IDR
Basic Features APERA, Benchtop Conductivity Meter Kit with TestBench EC950
Comes with Apera TestBench that incorporates a flexible electrode holder, an intelligent stirrer, and buffer organizers altogether, streamlining the process of pH measurement and calibration.
- intuitive operating navigation with natural language and graphics
- Multi-language operating system (English, German, Spanish, Mandarin)
- Automatic calibration, automatic temperature compensation, self-diagnosis.
- Manual data logger with 200 groups of storage
Conductivity Features
The 2401T-F glass conductivity/temp. electrode designed for research-level conductivity measurement from 0 to 200mS/cm at ±1% F.S accuracy
- 1 to 4 points automatic calibration with calibration instruction and self-diagnosis
- Single tap to switch from conductivity to TDS and salinity
- Automatically recognizes conductivity standard solution (84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm).
- Standard BNC conductivity connector, RCA connector for a temperature probe, NTC 30KΩ thermistor
Cond.
Measuring Range : Conductivity:0~200 mS/cm, divided into five ranges, automatically switch measuring range.
(0 to 19.99) μS/cm;
(20.0 to 199.9) μS/cm;
(200 to 1999) μS/cm;
(2.00 to 19.99) mS/cm;
(20.0 to 199.9) mS/cm
TDS: (0 to 100) g/L;
Salinity: (0 to 100) ppt
Resolution : 0.01/0.1/1μS/cm 0.01/0.1 mS/cm
Accuracy : ±1.0% FS ±1 digit
Temperature Compensation Range : (0 to 50)˚C (Auto. or Manual)
Cell constant : 0.1 / 1 / 10 cm-1
Temp. : Measuring Range : 0~100℃
Resolution : 0.1℃
Accuracy ±0.5℃±1 digit
Other Specifications
Data Storage : 100 groups
Storage Content : Number, measuring value and temperature value
Power : Input: 120V AC 60Hz; Output: DC9V/600mA, 2.7VA
Dimension & Weight : Meter:(195×215×100 )mm / 0.9kg
Connector : BNC for conductivity; RCA for temperature
What's in the box? : EC910 Meter, TestBench, 2401T-F conductivity/temp. electrode, 9V power adapter, flexible electrode holder, 50ml of
conductivity standards (84µS, 1413µS, 12.88mS), instruction manual
APERA DO850 Optical DO Meter
Rp
1
Rp
1
1.0
IDR
State-of-the-art Optical DO sensor measures dissolved oxygen in a RELIABLE and EFFORTLESS manner
Minimal maintenance required. Quick and easy calibration
Automatic compensation for salinity, temperature& air pressure
GLP/GMP data management, 500 groups of data storage, USB data output
Comes with a complete test kit, including the meter, 10ft optical probe and salinity probe, a calibration cap, and a rugged carrying case
Diameter of the probe cap for the DO803 Luminescent Optical DO Probe: approximately 1.3 inches (3.3 cm)
* DO
Range : ( 0‐20,00) mg /L ( ppm ) ( 0‐200)%
Resolution : 0,01/ 0,1 mg/L (ppm) , 0,1/1%
Accuracy : ±2% reading or ±2 % oxygen saturation take the higher value ; ±2% reading or ± 0,2 mg/L take the higher volume
Temp Compesation : 0 to 100 ◦C (32 to 212 ◦F) Automatic or manual
Calibration Point : Oxygen Saturation&Zero Oxygen
APERA, 3M KCl Solution(AgCl Saturation) Volume 250ml/bottle
Rp
1
Rp
1
1.0
IDR
APERA, Portable water hardness Meter YD300
Rp
1
Rp
1
1.0
IDR
The Apera Instruments YD300 is specially designed for fast and accurate measurement of water hardness (the concentration of calcium ions Ca2+ and magnesium ions Mg2+). The YD300 is equipped with a proprietary601-S water hardness electrode that has been proven to provide the same accuracy as the traditional volumetric EDTA method, but is much more convenient to perform measurements. Unlike the traditional EDTA method, it is not necessary to stir the samples or add reagents during measurements, and the ion concentration of the sample solutions can be measured directly as in pH measurements.
The meter uses an intelligent chip design that supports automatic calibration, data storage (up to 99 groups), and a low battery voltage indicator. The YD300 allows switching between eight common water hardness units, including mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler), mg/L (Ca), ˚fH (France Degree), ˚dH (German Degree), and ˚eH (England Degree).
Application of electrode method to measure hardness, with the same accuracy as EDTA titration method, but much more convenient.
Patented 601-S 3-in-1 water hardness electrode: combines a measuring electrode, a reference electrode and a temperature electrode in one instrument.
Intelligent chip design ensures stable performance potential, fast response time and convenient handling;
Store 99 data; automatic calibration and temperature compensation (ATC), automatic lockout and shutdown.
Portable IP57 waterproof design, equipped as a complete set with a rugged carrying case; suitable for laboratory and field use.
The YD300 is waterproof according to IP57 and is supplied as a complete set. This kit contains the Model 601-S water hardness electrode, water hardness calibration solutions (B1, B2 and B3); matching calibration bottles, water hardness activation solution, a 20 ml test cup, a test cup stand, 2 AA batteries and a quick reference guide in a rugged carrying case. Applications: potable water, wastewater, cooling towers, boilers, piping, aquaculture, pools & spas. Two-year manufacturer’s warranty on the device (6 months on the electrode).
Water Hardness : Measuring range (0 ~ 10) mmol/l; (0 ~ 401) mg/l(Ca);(0 ~ 1000) mg/l(CaCO3); (0 ~ 100)ºfH(French unit);
(0 ~ 561) mg/l(CaO); (0 ~ 56)ºdH(German unit);(0 ~ 20) mmol/l(kettle); (0 ~ 70) ºeH (English unit).
Resolution : 0.01 / 0.1 Water hardness units
Accuracy : ±5% F.S
Temperature compensation : (5 ~ 50°C)(automatic)
Calibration points : 2.00×10-2 mmol/l (B1 calibration solution), 2.00×10-1 mmol/l (B2 calibration solution)
2.00 mmol/l (B3 calibration solution)
Calibration mode : – B1/B2 calibration, suitable for low concentrated water (< 2.00×10-2 mmol/l), e.g. boiler water - B2/B3 calibration, suitable
for general water quality
Temperature : Recommended Operating temp. : 0 ~ 60°C (32 ~ 140°F)
Resolution : 0,1°C
Accuracy : ±0,5°C
Data storage : 99 groups
Storage data : Serial number of measured value, measured value, units, Temperature and calibration method
Power supply : 2 AA batteries (1.5V×2)
Dimensions/Weight : Gauge: (65×120×31) mm/180g; Carrying case: (255×210×50) mm/790g Quality and safety certificate
Ambient temperature : 5 ~ 35°C (41 ~ 95ºF)
Humidity : ≤85%
Housing protection class : IP57, dust and waterproof
Prev
1
2
Next