Categories
MILWAUKEE, pH Meter 101
Rp 1 Rp 1 1.0 IDR

Specifications

pH Range: 0.00 to 14.00 pH
pH Resolution: 0.01 pH
pH Accuracy: ±0.02 pH
Temperature Compensation: Manual, 0 to 50°C
Calibration: Manual, in 2 points through offset and slope trimmers
pH Electrode: SE220 with 3 foot cable (included)
Environment: 0 to 50°C / 32 to 122°F; max RH 95%
Battery Type: 1 x 9V (included)
Battery Life: Approx. 300 hours of continuous use
Dimensions: 5.7 x 3.1 x 1.6 inches
Weight: 7.8 ounces (with battery)

MILWAUKEE, High Range Free & Total Chlorine PRO Photometer
Rp 1 Rp 1 1.0 IDR
Specifications

Free and Total High Range Chlorine Photometer, Range: 0.00 to 10.00 mg/L of Cl2
Resolution: 0.01 mg/L (0.00 to 3.50 mg/L)
Resolution: 0.10 mg/L (above 3.50 mg/L)
Accuracy ± 0.17 mg/L @ 5.00 mg/L
Operating Environment: 0 to 50 C 32 to 122 F / Max. RH 100%
Light Source: Tungsten Lamp
Light Detector: Silicon photocell and 525 nm narrow band interference filter
Method: adaptation of USEPA method 330.5 & Standard Method 4500-Cl G
Battery Type: 1 X 9V (included)
Auto-off: after 10 minutes of non-use
Meter Dimensions / Weight: 7.5" x 4.1" x 2" / 0.84 lbs.
Packaging Dimensions / Weight: 12" x 11" x 4.5" / 2.7 lbs.
Meter Dimensions / Weight: 191 mm x 107 mm x 51 mm / 1.22 kg.
Packaging Dimensions / Weight: 305 mm x 280 mm x 115 mm / 1.5 kg.
Glass Cuvettes: MI0001 ( 2 x included)
MILWAUKEE, Free Chlorine Photometer
Rp 1 Rp 1 1.0 IDR
Description

The Milwaukee MI406 PRO Photometer features manual zero point calibration and fast operation in a rugged design.

The Milwaukee PRO Photometer is ideal for users in envoironmental, food, water treatment and lab applications. This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.

The Milwaukee PRO Photometer offers:
Speed

The MI406 microprocessor delivers fast results with accuracy of ±0.06 mg/L @ 1.50 mg/L and is repeatable.
Easy To Use and Toughness

This rugged meter is designed to take knocks. It's low maintenance design paired with easy to use reagents makes the MI406 ideal for everyone from educators and aquaculture, aquariums, environmental professionals to water treatment and food processing.
Design features

Fast easy to read results with large digital LCD readout.
Accurate to ±0.06 mg/L @ 1.50 mg/L and a range 0.00 to 5.00 mg/L of (Cl2 Free).
Lightweight and portable.
Easy measurement: just mix the reagent in the sample, gently shake, insert the cuvette, zero the meter then press read.
Simple easy reagent packets or liquid bottles.
Easy 1-2-3 instruction steps.
Auto shut off after 10 minutes of non-use, 9 volt (battery included).
Adaptation of The Nessler Method.

Built In Timer

MI406 has a built in timer that ensures appropriate reaction time is used for the chemical reaction. At the end of the timer, the meter will automatically take the reading. This feature ensures consistency across multiple users.
Cuvette Chamber

The MI406 has a built in indexing indent on the meter - The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.
Error Messaging

The MI406 has built in error messaging display alerts. This helps the user ensure no mistakes are made in the testing process. Messages include no cap, over range and under range, light source errors and zero cal error to ensure the user has the most accurate error free readings.
Calibration

The MI406 has a simple to use zero point calibration. Simply insert the unreacted sample cuvette into the chamber, index the cuvette and press the zero button. Your calibration is complete.
MILWAUKEE, Dosing Pump with adjustable dosing flow
Rp 1 Rp 1 1.0 IDR
Spesifikasi Produk


Model Number MP815
Unit 1pc
Adjustable Flow (L/h) 0.0 to 2.2
Max pressure (bar) 2
Squeeze Tubing Santropene
External Tube Connection (mm) 6
Power Supply (V/Hz) 240 AC/50-60
Power Consumption (W) 7.7
Berat (Kg) 20
Tanggal Produk Terdaftar 11 May 2023
Terakhir Diperbaharui 11 May 2023
APERA, Benchtop pH/Conductivity Meter Kit with TestBench
Rp 1 Rp 1 1.0 IDR
Basic Features APERA, Benchtop pH/Conductivity Meter Kit with TestBench

Comes with Apera TestBench that incorporates a flexible electrode holder, an intelligent stirrer, and buffer organizers altogether, streamlining the process of pH measurement and calibration.
Simultaneous measurement of pH and conductivity/TDS/salinity
Intuitive operating navigation with natural language and graphics
Multi-language operating system (English, German, Spanish, Mandarin)
Automatic calibration, automatic temperature compensation, self-diagnosis.
Manual data logger with 200 groups of storage

pH Features

Comes with the Swiss LabSen® 211 pH combination electrode and the MP500 temperature probe, achieving highly accurate measurements in the fastest manner
1 to 3 points automatic calibration with calibration instruction and self-diagnosis
Automatically recognizes pH standard solution (1.68, 4.00, 7.00, 10.01, 12.45). 3 series buffer standards for selection: USA, NIST, China series, as well as user-customized standards.
Automatically display electrode slope.
Standard BNC pH connector, RCA connector for a temperature probe, NTC 30KΩ thermistor

Conductivity Features
The 2401T-F glass conductivity/temp. electrode designed for research-level conductivity measurement from 0 to 200mS/cm at ±1% F.S
accuracy
1 to 4 points automatic calibration with calibration instruction and self-diagnosis
Automatically recognizes conductivity standard solution (84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm).
Standard BNC conductivity connector, RCA connector for a temperature probe, NTC 30KΩ thermistor
APERA, Benchtop Conductivity Meter Kit with TestBench
Rp 1 Rp 1 1.0 IDR
Basic Features APERA, Benchtop Conductivity Meter Kit with TestBench EC950

Comes with Apera TestBench that incorporates a flexible electrode holder, an intelligent stirrer, and buffer organizers altogether, streamlining the process of pH measurement and calibration.
- intuitive operating navigation with natural language and graphics
- Multi-language operating system (English, German, Spanish, Mandarin)
- Automatic calibration, automatic temperature compensation, self-diagnosis.
- Manual data logger with 200 groups of storage

Conductivity Features

The 2401T-F glass conductivity/temp. electrode designed for research-level conductivity measurement from 0 to 200mS/cm at ±1% F.S accuracy
- 1 to 4 points automatic calibration with calibration instruction and self-diagnosis
- Single tap to switch from conductivity to TDS and salinity
- Automatically recognizes conductivity standard solution (84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm).
- Standard BNC conductivity connector, RCA connector for a temperature probe, NTC 30KΩ thermistor

Cond.
Measuring Range : Conductivity:0~200 mS/cm, divided into five ranges, automatically switch measuring range.
(0 to 19.99) μS/cm;
(20.0 to 199.9) μS/cm;
(200 to 1999) μS/cm;
(2.00 to 19.99) mS/cm;
(20.0 to 199.9) mS/cm
TDS: (0 to 100) g/L;
Salinity: (0 to 100) ppt
Resolution : 0.01/0.1/1μS/cm 0.01/0.1 mS/cm
Accuracy : ±1.0% FS ±1 digit
Temperature Compensation Range : (0 to 50)˚C (Auto. or Manual)
Cell constant : 0.1 / 1 / 10 cm-1
Temp. : Measuring Range : 0~100℃
Resolution : 0.1℃
Accuracy ±0.5℃±1 digit

Other Specifications

Data Storage : 100 groups
Storage Content : Number, measuring value and temperature value
Power : Input: 120V AC 60Hz; Output: DC9V/600mA, 2.7VA
Dimension & Weight : Meter:(195×215×100 )mm / 0.9kg
Connector : BNC for conductivity; RCA for temperature
What's in the box? : EC910 Meter, TestBench, 2401T-F conductivity/temp. electrode, 9V power adapter, flexible electrode holder, 50ml of
conductivity standards (84µS, 1413µS, 12.88mS), instruction manual
APERA DO850 Optical DO Meter
Rp 1 Rp 1 1.0 IDR
State-of-the-art Optical DO sensor measures dissolved oxygen in a RELIABLE and EFFORTLESS manner
Minimal maintenance required. Quick and easy calibration
Automatic compensation for salinity, temperature& air pressure
GLP/GMP data management, 500 groups of data storage, USB data output
Comes with a complete test kit, including the meter, 10ft optical probe and salinity probe, a calibration cap, and a rugged carrying case
Diameter of the probe cap for the DO803 Luminescent Optical DO Probe: approximately 1.3 inches (3.3 cm)

* DO
Range : ( 0‐20,00) mg /L ( ppm ) ( 0‐200)%
Resolution : 0,01/ 0,1 mg/L (ppm) , 0,1/1%
Accuracy : ±2% reading or ±2 % oxygen saturation take the higher value ; ±2% reading or ± 0,2 mg/L take the higher volume
Temp Compesation : 0 to 100 ◦C (32 to 212 ◦F) Automatic or manual
Calibration Point : Oxygen Saturation&Zero Oxygen