Categories
MILWAUKEE, Refractometer Brix, model MA887
Rp 1 Rp 1 1.0 IDR
Range : 0 to 50 PSU: 0 to 150 ppt | 1.000 to 1.114 S.G. (20/20) | 0 to 80°C / 32 to 176°F
Resolution : 1 PSU | 1 ppt | 0.001 S.G. (20/20) | 0.1°C / 0.1°F
Accuracy : ±2 PSU | ±2 ppt | ±0.002 S.G. (20/20) | ±0.3°C / ±0.5°F
Light Source : Yellow LED
Measurements Time : Approximately 1.5 seconds
Minimum Sample : Volume 100 µL (cover prism totally)
Sample Cell : Stainless steel ring and flint glass prism
Temperature Compensation : Automatic between 10 and 40°C / 50 to 104°F
Case Material : ABS
Battery : Type 1 x 9V AA (included)
Battery Life : 5000 readings
Auto-shut off : After 3 minutes of non-use
Enclosure Rating : IP65
Dimensions Meter : 7.6 x 4 x 2.64 inches (192 x 102 x 67 mm)
Weight Meter : 93 lbs. (0.42 kg)
Dimensions Package : 11 x 6.8 x 4.6 inches (268 x 172 x 118 mm)
Weight Packaged : 1.46 lbs. (0.66 kg)
PCRMax, Alpha cycler 4 chassis with four 96 well blocks
Rp 1 Rp 1 1.0 IDR
Technical Specifications PCRMax Alpha cycler 4

KEY FEATURES PCRMax Alpha cycler 4
• Android interface – A large 10 inch colour touchscreen interface powered by a Quad core processor provides a fast, clear and intuitive user experience
• Robust build and reliable system, made with a steel chassis and durable top moulding
• Compact- Save valuable benchspace by condensing four truly independent blocks into one chassis with no connectivity or network issues
• Program Wizard- Generate a protocol specific to your template length, sequence and amplicon size in seconds
• Gradient- Simplified temperature optimization
• Quiet operation – Low fan noise even when all four blocks are in operation
• Format flexibility- The AC-4 is available with any combination of 96 or 384 well blocks
• USB connectivity- For easy transfer of protocols between instruments and retrieval of system information
• Reports- Following completion of a run, a comprehensive report of state and run conditions is generated
• Active Sample Cooling- Minimise non-specific amplification and achieve sharper amplification
• 2 Year manufacturer warranty as standard
• Free software upgrades for the life of the system

TECHNICAL SPECIFICATION
Unit : AC-4
Format : Quad block
Block Options : 96 or 384 well format
Maximum heating rate : 3.4°C per second
Block temperature range : 10°C to 100°C (4°C final hold)
Block uniformity at 55°C : ± 0.3°C
Temperature accuracy at 55°C: : ± 0.25°C
Gradient : Yes (on all formats)
Maximum Gradient : 29°C
Minimum Gradient : 1°C
Maximum number of programs stored : 1000
Maximum fan noise : 50dB single block running, 55-58db four blocks running
Peltier element type : 6
Adjustable heated lid temperature : 35°C to 115°C or off
Heated lid pressure : Adjustable
Software platform : Android
Program interface : 10” inch 1080p HD
Data transfer : USB port
Auto re-start on power failure : Yes
Dimensions (L x W x H) in mm 700 x 535 x 200
Weight : 45kg
Voltage : 100-230, 50-60Hz
Power : 450W
Electricity (standard 30 cycle program) 0.3 kWh
Alpha Cycler 4 with four 96 well blocks
PCRMax, Alpha cycler 1 chassis with a single 96 well block
Rp 1 Rp 1 1.0 IDR
The PCRmax Alpha cyclers are developed to deliver not only the best quality data you can expect from PCRmax but also to innovate and exceed the high standards expected by the community.

Alpha Cycler software has features such as recently used programmes; allowing users to quickly access their most commonly used protocols without the need to navigate through folders to find it, individual user logins; with protected protocols as-well-as allowing users’ access to temperature logs after each run to monitor the state of the system.

The Alpha Cycler systems also contain a novel programme wizard which allows users to define a protocol based specifically off their primer sequence and template source. Primer sequences or Tms are inputted, amplicon length and source defined and the on board algorithm generates an optimised protocol for your assay.

Technical Specifications PCRMax Alpha cycler 1 96 well block

Format: Single block
Block Options: 96 or 384 well format
Maximum heating rate: 3.4°C per second
Block temperature range: 10°C to 100°C (4°C final hold)
Block uniformity at 55°C: ± 0.3°C
Temperature accuracy at 55°C: ± 0.25°C
Gradient: Yes (on all formats)
Maximum Gradient: 29°C
Minimum Gradient: 1°C
Maximum number of programs stored: 1000
Maximum fan noise: 50dB
Type: 8 peltier elements
Adjustable heated lid temperature: 35°C to 115°C or off
Heated lid pressure: Adjustable
Program interface: 7” inch HD Android Tablet
Data transfer: USB port
Auto re-start on power failure: Yes
Dimensions (L x W x H) in mm: 430 x 260 x 200
Weight: 11.8kg
Voltage: 100-230, 50-60Hz
Power: 450W
Electricity used in a standard 2 step, 30 cycle program: 0.3 kWh
MILWAUKEE, Oxygen electrolyte solution (230 mL) for MW600
Rp 1 Rp 1 1.0 IDR
DESIGN FEATURES

Fast, easy-to-read results with large digital LCD readout
Repeatable, accuracy to ±1.5% FS
Lightweight and portable
Simple 2 point open air calibration (see video below)
Uses MA840 reinforced polarographic probe with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor
5 o-rings, membranes and one protective cap included
10 feet probe cable for extra flexibility when testing
70 hours of battery life with continuous use (battery included) with low battery warning


CARE AND USE

“OPEN AIR” CALIBRATION PROCEDURE

1. Remove the membrane
Take the membrane off the end of the probe and dry the diode off.

2. Zero out the display
Connect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0.

3. Fill the membrane
Go to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure)

4. Attach the membrane
Screw the membrane on to the probe.

5. Let stablize
Turn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes)

6. Adjust
Push down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100.

You are now calibrated.


EXTRA TIPS

Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.
Always use fresh electrolyte solution (MA9071).


SPECIFICATIONS

O2 Range: 0.0 to 19.9 mg/L
O2 resolution: 0.1 mg/L
O2 Accuracy: ±1.5% Full Scale
Calibration: Manual on 2 points (zero and slope)
Temperature Compensation: Automatic, from 0 to 30°C
Probe: MA840 refillable polarographic probe included
Membranes: 5 included
Environment: 0 to 50°C / 32 to 122°F; max RH 95%
Battery Type: 1 x 9V alkaline (included)
Battery Life: Approx. 70 hours of continuous use
Dimensions: 5.7 x 3.1 x 1.6 inches
Weight: 7.5 ounces with battery
Milwaukee MI411 pH and Free & Total Chlorine PRO Photometer
Rp 1 Rp 1 1.0 IDR
The Milwaukee MI411 PRO Photometer features manual zero point calibration and fast operation in a rugged design.

The Milwaukee PRO Photometer is ideal for users in pools, aquaculture, water conditioning applications. This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.

SPECIFICATIONS

Free and Total Chlorine Photometer, Range: 0.00 to 5.00 mg/L of Cl2 | pH Range: 6.5 to 8.0 pH
Free & Total Chlorine Resolution: 0.01 mg/L (0.00 to 3.50 mg/L)
Free & Total Chlorine Resolution: 0.10 mg/L (above 3.50 mg/L)
pH Resolution: 0.1 pH
Accuracy ± 0.06 mg/L @ 1.50 mg/L (Cl) | pH ± 0.1 @ 7.2 pH
Method: adaptation of USEPA method 330.5 & Standard Method 4500-Cl G (Cl) | pH adaptation of red phenol method
Light Source: Tungsten Lamp
Light Detector: Silicon photocell and 525 nm narrow band interference filter
Operating Environment: 0 to 50 C 32 to 122 F / Max. RH 100%
Battery Type: 1 X 9V (included)
Auto-off: after 10 minutes of non-use
Meter Dimensions / Weight: 7.5" x 4.1" x 2" / 0.84 lbs.
Packaging Dimensions / Weight: 12" x 11" x 4.5" / 2.7 lbs.
Meter Dimensions / Weight: 191 mm x 107 mm x 51 mm / 1.22 kg.
Packaging Dimensions / Weight: 305 mm x 280 mm x 115 mm / 1.5 kg.
Glass Cuvettes: MI0001 ( 2 x included)
IDEXX, TECTAB16A-230-02 AUTOMATED MICROBIOLOGY DETECTION SYSTEM, 230V
Rp 1 Rp 1 1.0 IDR
Technical Specifications IDEXX TECTAB16


Specification
Operating Principal :
•The IDEXX TECTA™ B16 is a complete, self-contained automated microbiology testing
system capable of providing laboratory-grade results on-site with unprecedented
time-to-result performance.

Operating Principal :
Broad-spectrum E. coli (glucuronidase enzyme)
Total Coliforms (galactosidase enzyme)
Fecal Coliforms (galactosidase enzyme)
Enterococcus (glucosidase enzyme)

Instrument Capacity : Up to 16 simultaneous tests for presence/absence with optional quantitative reporting in CFU per 100ml on positive results

Sample Handling : Manual sample acquisition with Direct-to-Test capability eliminates sample handling and mixing of reagents.

Range : Dynamic range of <1 to >10⁸ CFU in 100 ml without requirement for sample dilution.

Operating Modes : Fully automated monitoring, interpretation and reporting of results. All results available locally or remotely via email (network connection required). Automatic system confirmation and calibration.
Run Mode – Incubation and interpretation in 2-18 hours.
Read Mode – Interpretation of pre-incubated samples in 60 seconds.

Typical Detection Times :
1. TECTAlert-ECA, E.Coli
< 1 CFU/100 ml : within 16 hrs
100 CFU/100 ml : within 9 hrs
1,000 CFU/100 ml : within 8 hrs
10 CFU/100 ml : within 4 hrs

2. TECTAlert-FCA, Fecal Coliform
< 1 CFU/100 ml : within 18 hrs
100 CFU/100 ml : within 10 hrs
1,000 CFU/100 ml : within 9 hrs
10 CFU/100 ml : within 5 hrs

3. TECTAlert-CCA, Total Coliform & E.Coli
< 1 CFU/100 ml : within 18 hrs
100 CFU/100 ml : within 12 hrs
1,000 CFU/100 ml : within 11 hrs
10 CFU/100 ml : within 7 hrs

4. TECTAlert-ENA, Enterococcus
< 1 CFU/100 ml : within 24 hrs
100 CFU/100 ml : within 12 hrs
1,000 CFU/100 ml : within 10 hrs
10 CFU/100 ml : within 4 hrs

User Interface : 7” (17.7 cm) front touch-screen display controls all functions. USB keyborad port optl.
Power Supply :120 VAC / 220 VAC versions available (must specify).
Weight (Installed) :Approximately 21 Kg / 463 lbs


Include Catridge :
TECTAlertCCA combined E.coli and Total coliform test 48 test/box
APERA, Purified Water pH Meter (Drinking water.purified water,deionized water etc) Model PH850-PW
Rp 1 Rp 1 1.0 IDR
Technical Specification
Carrying caseing including solutions: YesElectrodes: LabSen803
IP Rating: IP57
Datalogger: No
Date and Time: No
Output: No
Features
:
This Portable pH Meter has a ±0.01 pH accuracy in a range of 0-14 pH, and Temperature Range: 0 to 80°C(32 to 176°F), Auto Calibration with auto-recognition of up to 12 kinds of buffer solutions, Auto. Temp. Compensation, and supports stable reading/auto-hold display mode.

Intelligent Functions: Self Diagnosis reminds of out-of-range measurement, incorrect calibration, and electrode invalidation. Other functions include auto. calibration, auto. lock, easy parameter settings, pH electrode's slope display, auto. power off, etc.

Reliable Structure Design: foldable stand allows use as a benchtop meter; The rubber boot gives you a nice and firm grip; IP57 waterproof rating; Powered by 3 AA alkaline batteries.

Technical Specs

pH Range: 0 to 14 pH

Resolution: 0.01/0.1 pH

Accuracy: ±0.01 pH ±1 digit

Temperature Compensation: 0 to 100°C (Auto or Manual)

mV Range: -1000 mV - 0 - 1000 mV

Resolution: 1 mV

Accuracy: ±0.2% F.S ±1 digit

Temp Range: 0 to 100°C (23 to 212°F)

Resolution: 0.1°C

Accuracy: ±0.5°C ±1 digit

Other Specs

AA Batteries * 3 / DC5V (USB port)

IP Ranking: IP57 dust-proof and waterproof

Dimensions& Weight Meter: (88_170_33 ) mm/ 313g With case_(360_270_76) mm/ 1.6kg

pH Electrode (LabSen 803) Specs

Housing Material: Lead-free glass

Temperature sensor: Yes

Junction: Movable sleeve

Reference Electrode: Silver ion trap

Electrolyte: 3M KCL

Shape of glass membrane: Cylindrical

Range: 1 to 11 pH

Temperature Range: 0 to 80°C (32 to 176°F)