Categories
Milwaukee MA917B/1 Refillable Combination pH Probe
Rp 1 Rp 1 1.0 IDR
SPECIFICATIONS

Body: Glass
Reference: Double, Ag/AgCl
Junction: Ceramic, Single
Electrolyte: 3.5M KCl
Range: 0-14 pH
Tip Shape: Sphere
Diameter: 0.5 inches
Dimensions: 4.7 inches / 6.4 inches
Operating Temperature: 68 to 104°F)
Cable length: 3.3 feet
Connection: BNC
Milwaukee MI411 pH and Free & Total Chlorine PRO Photometer
Rp 1 Rp 1 1.0 IDR
The Milwaukee MI411 PRO Photometer features manual zero point calibration and fast operation in a rugged design.

The Milwaukee PRO Photometer is ideal for users in pools, aquaculture, water conditioning applications. This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.

SPECIFICATIONS

Free and Total Chlorine Photometer, Range: 0.00 to 5.00 mg/L of Cl2 | pH Range: 6.5 to 8.0 pH
Free & Total Chlorine Resolution: 0.01 mg/L (0.00 to 3.50 mg/L)
Free & Total Chlorine Resolution: 0.10 mg/L (above 3.50 mg/L)
pH Resolution: 0.1 pH
Accuracy ± 0.06 mg/L @ 1.50 mg/L (Cl) | pH ± 0.1 @ 7.2 pH
Method: adaptation of USEPA method 330.5 & Standard Method 4500-Cl G (Cl) | pH adaptation of red phenol method
Light Source: Tungsten Lamp
Light Detector: Silicon photocell and 525 nm narrow band interference filter
Operating Environment: 0 to 50 C 32 to 122 F / Max. RH 100%
Battery Type: 1 X 9V (included)
Auto-off: after 10 minutes of non-use
Meter Dimensions / Weight: 7.5" x 4.1" x 2" / 0.84 lbs.
Packaging Dimensions / Weight: 12" x 11" x 4.5" / 2.7 lbs.
Meter Dimensions / Weight: 191 mm x 107 mm x 51 mm / 1.22 kg.
Packaging Dimensions / Weight: 305 mm x 280 mm x 115 mm / 1.5 kg.
Glass Cuvettes: MI0001 ( 2 x included)
Milwaukee pH/Temperature Bench Meter
Rp 1 Rp 1 1.0 IDR
Specifications

pH Range: -2.00 to 20.00 pH
ORP Range: ±2000.0mV
Temp. Range: -20.0 to 120.00°C (-4.0 to 248.0°F)
Resolution: 0.01 pH
Resolution: 0.1mV
Resolution: 0.1°C (0.1°F)
Accuracy: ±0.01 pH @ 25°C / 77°F
Accuracy: ±1mV
Accuracy: ±0.4°C | ±0.8°F
pH Calibration: up to 3 point automatic pH calibration | 7 standard buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)
Temperature Compensation: Automatic, -20.0 to 120.0°C (-4.0 to 248.0°F) or manual (without temperature probe)
pH electrode: MA917B/1 glass, double junction pH electrode (supplied)
Temperature probe: MA831R temperature probe (supplied)
Power supply: 12VDC (included)
Battery life: Approx. 8 hours of use
Auto-off: Selectable 5, 10, 30, 60 min. or off
Environment: 0 to 50°C / 32 to 122°F; max RH 95%
Dimensions: 230 x 160 x 95 mm (9.0 x 6.3 x 3.7")
Weight: 0.9 kg / (2.0 lbs)
Warranty: 3 years Meter
Milwaukee, Pocket-Sized Thermometer with Automatic Calibration Check
Rp 1 Rp 1 1.0 IDR
Specifications

Temperature Range: -50 to 150°C Readings in Celsius Only (-58 to 302°F)
Resolution: 0.1°C
Accuracy: ± 0.5°C (-20 to 90°C)
Typical EMC Deviation: ±0.3°C
Probe: Stainless Steel
Environment: 0 to 50°C (32°F to 122°F), 95% RH
Battery Life: approx. 3000 hours of continuous
Battery Type: 1 x 1.5V (included)
Package Dimensions: 10 x 2.6 x 1.9 inches (254 x 67 x 47 mm)
Packaged Weight: 3.5 ounces (100 g)
Warranty:
Milwaukee, Watefproof pH/Meter
Rp 1 Rp 1 1.0 IDR
Specifications

pH Range: 0.0 to 14.0 pH
pH Resolution: 0.1 pH
pH Accuracy: ±0.1 pH
Typical EMC Deviation: ±0.1
Calibration: Manual, 1 or 2 points
Probe: Replaceable double junction for extended life (MA73600)
Environment: 0 to 50°C / 32 to 122°F; max RH 100%
Battery Type: 3 x 1.5V; IEC LR44, A76 (included)
Battery Life: Approx. 1500 hours of continious use
Dimensions: 7.9 inches × 1.5 inches (diameter)
Weight: 3.5 ounces (99.22 g)
Milwaukee, pH meter pocket with temperature
Rp 1 Rp 1 1.0 IDR
Model Number pH55
Unit 1pc
Battery Type (V) 4x1.5, IEC LR44, A76 (Included)
Probe Replaceable Double Jjunction For Extended Life (Mi56P)
Resolution (pH) 0.1
pH Accuracy (pH) ±0.1
Environment (°C) -5-50 Max RH 100%
Temperature Range (°C) -5.0 to 60.0
Temperature Compensation (°C) Automatic From -5 to 60
Battery Life (hours) ±300 Of Use
Dimensions (mm) 254×67×47
Temperature Accuracy (°C) ±0.5
Auto-Off (minutes) After 8 Of Non-Use
Calibration Automatic 1 or 2 Points With 2 Sets Of Pre-Memorized Buffers (pH 4.01, 7.01, 10.01) or (pH 4.01, 6.86, 9.18)
Typical EMC Deviation Temperature (°C) ±0.3
pH Range (pH) -2.0 to 16.0
Typical EMC Deviation ±0.1
Berat (Kg) 3