Categories
MILWAUKEE, Portable Dissolved Oxygen Meter - DO Meter
Rp 1 Rp 1 1.0 IDR
MW600 Standard Portable Dissolved Oxygen Meter
Spesifikasi :
O2 Range : 0.0 to 19.9 mg/l
O2 resolution : 0.1 mg/l
O2 Accuracy : ±1.5% Full Scale
Calibration : manual on 2 points (zero and slope)
Temperature Compensation : automatic, from 0 to 30°C
Probe : MA840 (included)
Polarographic D.O. probe with 3 meters cable
Environment 0 to 50°C / 32 to 122°F; max RH 95%
Battery Type 1 x 9V alkaline (included)
Battery Life : approx. 70 hours of continuous use
Dimensions : 145 x 80 x 40 mm

MW600 is supplied complete with MA840 probe, 2 spare membranes, 20 mL bottle of electrolyte solution, calibration screwdriver, instructions and 9V battery
MILWAUKEE, 100 Reagents for pH Photometer
Rp 1 Rp 1 1.0 IDR
Description :

The MI509-100 pH liquid reagent kit includes high-quality reagents that are ready-to-use with Milwaukee's pH, Free & Total Chlorine photometer MI411. The reagents and the meter use the adaptation of USEPA Method 330.5 and Standard Method 4500- CL G & adaptation of the phenol red method. Simply add the reagent to the sample, wait for the reaction to take place and the photometer determines the concentration based on the color. The reagents are designed for use with samples that have an expected range of 6.5 to 8.00 pH.

Design Features

- pH 6.5 to 8.0 Range reagent replacement kit (100 tests).
- Pre-made reagents for precision and ease of use.
- Marked with expiration date and lot number for traceability.
- For use with the MI411 Meter.
MILWAUKEE, Conductivity / TDS / NaCl / Temperature Professional Portable Meter
Rp 1 Rp 1 1.0 IDR
Spesifikasi Produk

Model Number MW301
Unit 1unit
Conductivity Probe SE510
Range (µS/cm) 0 to 1990
Range (μS/cm) 0 to 1990
Resolution (μS/cm) 1
Environment (°C) 0 to 50
Environment (%) Max RH 95
Temperature Compensation (°C) Automatic, from 5 to 50
Battery Life (h) Approx. 300 of Continuous Use
Dimensions (inch) 5.6x3.1x1.25
Accuracy (%) ±2 Full Scale
Battery Type (V) 1x9 Alkaline
Berat (Kg) 0.2
Tanggal Produk Terdaftar 22 June 2023
Terakhir Diperbaharui 25 July 2023
MILWAUKEE, Conductivity Meter
Rp 1 Rp 1 1.0 IDR
Spesifikasi Produk

Model Number MW301
Unit 1unit
Conductivity Probe SE510
Range (µS/cm) 0 to 1990
Range (μS/cm) 0 to 1990
Resolution (μS/cm) 1
Environment (°C) 0 to 50
Environment (%) Max RH 95
Temperature Compensation (°C) Automatic, from 5 to 50
Battery Life (h) Approx. 300 of Continuous Use
Dimensions (inch) 5.6x3.1x1.25
Accuracy (%) ±2 Full Scale
Battery Type (V) 1x9 Alkaline
Berat (Kg) 0.2
Tanggal Produk Terdaftar 22 June 2023
Terakhir Diperbaharui 25 July 2023
MILWAUKEE, Digital Brix Refractometer
Rp 1 Rp 1 1.0 IDR
Description

The Milwaukee digital BRIX refractometer is temperature compensated with a 0 to 85 percent BRIX range and +/- 0.2 percent accuracy. It is easy to use with simple two button operation and fast with a response time under 2 seconds. Maintenance is a breeze also with an easy-to-clean sealed flint glass prism and stainless steel well.

Feature

Design features
-Fast, accurate results with digital dual level LCD readout.
-Easy measurement with just 2-3 drops of sample needed and results less than 2 seconds.
-Simple one-point calibration using distilled or deionized water.
-Easy to clean, stainless steel sample well with unit rated to IP65 as "dust tight" and protected against water jets.
-Battery percent level indicator with automatic shut-off (batteries included).
-Ideal for winemakers, brewers, fruit and vegetable growers, maple syrup producers, and food producers.
-The measurement technique and temperature compensation employ methodology recommended in the ICUMSA Methods Book (Internationally recognized body for Sugar Analysis).
MILWAUKEE, Dosing Pump with adjustable dosing flow
Rp 1 Rp 1 1.0 IDR
Spesifikasi Produk


Model Number MP815
Unit 1pc
Adjustable Flow (L/h) 0.0 to 2.2
Max pressure (bar) 2
Squeeze Tubing Santropene
External Tube Connection (mm) 6
Power Supply (V/Hz) 240 AC/50-60
Power Consumption (W) 7.7
Berat (Kg) 20
Tanggal Produk Terdaftar 11 May 2023
Terakhir Diperbaharui 11 May 2023
MILWAUKEE, Free & Total Chlorine PRO Photometer
Rp 1 Rp 1 1.0 IDR
Description

The Milwaukee MI404 PRO Photometer features manual zero point calibration and fast operation in a rugged design.
The Milwaukee PRO Photometer is ideal for users in pools, brewing, winemaking, and hydroponic applications. This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.
The Milwaukee PRO Photometer offers:

Speed
The MI404 microprocessor delivers fast results with accuracy of ±0.06 mg/L @ 1.50 mg/L and is repeatable.

Easy To Use and Toughness
This rugged meter is designed to take knocks. It's low maintenance design paired with easy to use reagents makes the MI404 ideal for everyone from educators and pool professionals to brewers and growers.

Design features

Fast easy to read results with large digital LCD readout.
Accurate to ±0.06 mg/L @ 1.50 mg/L and a range 0.00 to 5.00 mg/L of Cl2.
Lightweight and portable.
Easy measurement: just mix the reagent in the sample, gently shake, insert the cuvette, zero the meter then press read.
Simple easy reagent packets or liquid bottles.
Easy 1-2-3 instruction steps.
Auto shut off after 10 minutes of non-use, 9 volt (battery included).
Adaptation of USEPA Method 330.5 and Standard Method 4500- CL G.
Built In Timer

MI404 has a built in timer that ensures appropriate reaction time is used for the chemical reaction. At the end of the timer, the meter will automatically take the reading. This feature ensures consistency across multiple users.
Cuvette Chamber

The MI404 has a built in indexing indent on the meter - The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.
Error Messaging

The MI404 has built in error messaging display alerts. This helps the user ensure no mistakes are made in the testing process. Messages include no cap, over range and under range, light source errors and zero cal error to ensure the user has the most accurate error free readings.
Calibration

The MI404 has a simple to use zero point calibration. Simply insert the unreacted sample cuvette into the chamber, index the cuvette and press the zero button. Your calibration is complete.
MILWAUKEE, Free Chlorine Photometer
Rp 1 Rp 1 1.0 IDR
Description

The Milwaukee MI406 PRO Photometer features manual zero point calibration and fast operation in a rugged design.

The Milwaukee PRO Photometer is ideal for users in envoironmental, food, water treatment and lab applications. This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.

The Milwaukee PRO Photometer offers:
Speed

The MI406 microprocessor delivers fast results with accuracy of ±0.06 mg/L @ 1.50 mg/L and is repeatable.
Easy To Use and Toughness

This rugged meter is designed to take knocks. It's low maintenance design paired with easy to use reagents makes the MI406 ideal for everyone from educators and aquaculture, aquariums, environmental professionals to water treatment and food processing.
Design features

Fast easy to read results with large digital LCD readout.
Accurate to ±0.06 mg/L @ 1.50 mg/L and a range 0.00 to 5.00 mg/L of (Cl2 Free).
Lightweight and portable.
Easy measurement: just mix the reagent in the sample, gently shake, insert the cuvette, zero the meter then press read.
Simple easy reagent packets or liquid bottles.
Easy 1-2-3 instruction steps.
Auto shut off after 10 minutes of non-use, 9 volt (battery included).
Adaptation of The Nessler Method.

Built In Timer

MI406 has a built in timer that ensures appropriate reaction time is used for the chemical reaction. At the end of the timer, the meter will automatically take the reading. This feature ensures consistency across multiple users.
Cuvette Chamber

The MI406 has a built in indexing indent on the meter - The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.
Error Messaging

The MI406 has built in error messaging display alerts. This helps the user ensure no mistakes are made in the testing process. Messages include no cap, over range and under range, light source errors and zero cal error to ensure the user has the most accurate error free readings.
Calibration

The MI406 has a simple to use zero point calibration. Simply insert the unreacted sample cuvette into the chamber, index the cuvette and press the zero button. Your calibration is complete.