Categories
Milwaukee MI411 pH and Free & Total Chlorine PRO Photometer
Rp 1 Rp 1 1.0 IDR
The Milwaukee MI411 PRO Photometer features manual zero point calibration and fast operation in a rugged design.

The Milwaukee PRO Photometer is ideal for users in pools, aquaculture, water conditioning applications. This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.

SPECIFICATIONS

Free and Total Chlorine Photometer, Range: 0.00 to 5.00 mg/L of Cl2 | pH Range: 6.5 to 8.0 pH
Free & Total Chlorine Resolution: 0.01 mg/L (0.00 to 3.50 mg/L)
Free & Total Chlorine Resolution: 0.10 mg/L (above 3.50 mg/L)
pH Resolution: 0.1 pH
Accuracy ± 0.06 mg/L @ 1.50 mg/L (Cl) | pH ± 0.1 @ 7.2 pH
Method: adaptation of USEPA method 330.5 & Standard Method 4500-Cl G (Cl) | pH adaptation of red phenol method
Light Source: Tungsten Lamp
Light Detector: Silicon photocell and 525 nm narrow band interference filter
Operating Environment: 0 to 50 C 32 to 122 F / Max. RH 100%
Battery Type: 1 X 9V (included)
Auto-off: after 10 minutes of non-use
Meter Dimensions / Weight: 7.5" x 4.1" x 2" / 0.84 lbs.
Packaging Dimensions / Weight: 12" x 11" x 4.5" / 2.7 lbs.
Meter Dimensions / Weight: 191 mm x 107 mm x 51 mm / 1.22 kg.
Packaging Dimensions / Weight: 305 mm x 280 mm x 115 mm / 1.5 kg.
Glass Cuvettes: MI0001 ( 2 x included)
MILWAUKEE, Oxygen electrolyte solution (230 mL) for MW600
Rp 1 Rp 1 1.0 IDR
DESIGN FEATURES

Fast, easy-to-read results with large digital LCD readout
Repeatable, accuracy to ±1.5% FS
Lightweight and portable
Simple 2 point open air calibration (see video below)
Uses MA840 reinforced polarographic probe with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor
5 o-rings, membranes and one protective cap included
10 feet probe cable for extra flexibility when testing
70 hours of battery life with continuous use (battery included) with low battery warning


CARE AND USE

“OPEN AIR” CALIBRATION PROCEDURE

1. Remove the membrane
Take the membrane off the end of the probe and dry the diode off.

2. Zero out the display
Connect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0.

3. Fill the membrane
Go to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure)

4. Attach the membrane
Screw the membrane on to the probe.

5. Let stablize
Turn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes)

6. Adjust
Push down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100.

You are now calibrated.


EXTRA TIPS

Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.
Always use fresh electrolyte solution (MA9071).


SPECIFICATIONS

O2 Range: 0.0 to 19.9 mg/L
O2 resolution: 0.1 mg/L
O2 Accuracy: ±1.5% Full Scale
Calibration: Manual on 2 points (zero and slope)
Temperature Compensation: Automatic, from 0 to 30°C
Probe: MA840 refillable polarographic probe included
Membranes: 5 included
Environment: 0 to 50°C / 32 to 122°F; max RH 95%
Battery Type: 1 x 9V alkaline (included)
Battery Life: Approx. 70 hours of continuous use
Dimensions: 5.7 x 3.1 x 1.6 inches
Weight: 7.5 ounces with battery
PCRMax, Alpha cycler 1 chassis with a single 96 well block
Rp 1 Rp 1 1.0 IDR
The PCRmax Alpha cyclers are developed to deliver not only the best quality data you can expect from PCRmax but also to innovate and exceed the high standards expected by the community.

Alpha Cycler software has features such as recently used programmes; allowing users to quickly access their most commonly used protocols without the need to navigate through folders to find it, individual user logins; with protected protocols as-well-as allowing users’ access to temperature logs after each run to monitor the state of the system.

The Alpha Cycler systems also contain a novel programme wizard which allows users to define a protocol based specifically off their primer sequence and template source. Primer sequences or Tms are inputted, amplicon length and source defined and the on board algorithm generates an optimised protocol for your assay.

Technical Specifications PCRMax Alpha cycler 1 96 well block

Format: Single block
Block Options: 96 or 384 well format
Maximum heating rate: 3.4°C per second
Block temperature range: 10°C to 100°C (4°C final hold)
Block uniformity at 55°C: ± 0.3°C
Temperature accuracy at 55°C: ± 0.25°C
Gradient: Yes (on all formats)
Maximum Gradient: 29°C
Minimum Gradient: 1°C
Maximum number of programs stored: 1000
Maximum fan noise: 50dB
Type: 8 peltier elements
Adjustable heated lid temperature: 35°C to 115°C or off
Heated lid pressure: Adjustable
Program interface: 7” inch HD Android Tablet
Data transfer: USB port
Auto re-start on power failure: Yes
Dimensions (L x W x H) in mm: 430 x 260 x 200
Weight: 11.8kg
Voltage: 100-230, 50-60Hz
Power: 450W
Electricity used in a standard 2 step, 30 cycle program: 0.3 kWh
PCRMax, Alpha cycler 4 chassis with four 96 well blocks
Rp 1 Rp 1 1.0 IDR
Technical Specifications PCRMax Alpha cycler 4

KEY FEATURES PCRMax Alpha cycler 4
• Android interface – A large 10 inch colour touchscreen interface powered by a Quad core processor provides a fast, clear and intuitive user experience
• Robust build and reliable system, made with a steel chassis and durable top moulding
• Compact- Save valuable benchspace by condensing four truly independent blocks into one chassis with no connectivity or network issues
• Program Wizard- Generate a protocol specific to your template length, sequence and amplicon size in seconds
• Gradient- Simplified temperature optimization
• Quiet operation – Low fan noise even when all four blocks are in operation
• Format flexibility- The AC-4 is available with any combination of 96 or 384 well blocks
• USB connectivity- For easy transfer of protocols between instruments and retrieval of system information
• Reports- Following completion of a run, a comprehensive report of state and run conditions is generated
• Active Sample Cooling- Minimise non-specific amplification and achieve sharper amplification
• 2 Year manufacturer warranty as standard
• Free software upgrades for the life of the system

TECHNICAL SPECIFICATION
Unit : AC-4
Format : Quad block
Block Options : 96 or 384 well format
Maximum heating rate : 3.4°C per second
Block temperature range : 10°C to 100°C (4°C final hold)
Block uniformity at 55°C : ± 0.3°C
Temperature accuracy at 55°C: : ± 0.25°C
Gradient : Yes (on all formats)
Maximum Gradient : 29°C
Minimum Gradient : 1°C
Maximum number of programs stored : 1000
Maximum fan noise : 50dB single block running, 55-58db four blocks running
Peltier element type : 6
Adjustable heated lid temperature : 35°C to 115°C or off
Heated lid pressure : Adjustable
Software platform : Android
Program interface : 10” inch 1080p HD
Data transfer : USB port
Auto re-start on power failure : Yes
Dimensions (L x W x H) in mm 700 x 535 x 200
Weight : 45kg
Voltage : 100-230, 50-60Hz
Power : 450W
Electricity (standard 30 cycle program) 0.3 kWh
Alpha Cycler 4 with four 96 well blocks
MILWAUKEE, Refractometer Brix, model MA887
Rp 1 Rp 1 1.0 IDR
Range : 0 to 50 PSU: 0 to 150 ppt | 1.000 to 1.114 S.G. (20/20) | 0 to 80°C / 32 to 176°F
Resolution : 1 PSU | 1 ppt | 0.001 S.G. (20/20) | 0.1°C / 0.1°F
Accuracy : ±2 PSU | ±2 ppt | ±0.002 S.G. (20/20) | ±0.3°C / ±0.5°F
Light Source : Yellow LED
Measurements Time : Approximately 1.5 seconds
Minimum Sample : Volume 100 µL (cover prism totally)
Sample Cell : Stainless steel ring and flint glass prism
Temperature Compensation : Automatic between 10 and 40°C / 50 to 104°F
Case Material : ABS
Battery : Type 1 x 9V AA (included)
Battery Life : 5000 readings
Auto-shut off : After 3 minutes of non-use
Enclosure Rating : IP65
Dimensions Meter : 7.6 x 4 x 2.64 inches (192 x 102 x 67 mm)
Weight Meter : 93 lbs. (0.42 kg)
Dimensions Package : 11 x 6.8 x 4.6 inches (268 x 172 x 118 mm)
Weight Packaged : 1.46 lbs. (0.66 kg)
APERA, Portable Turbidity Meter Kit
Rp 1 Rp 1 1.0 IDR
APERA Portable Turbidity Meter Kit: Alat pengukur kekeruhan ini dirancang untuk memberikan hasil yang akurat dan konsisten dalam pengujian kualitas air. Dengan fitur portabel, alat ini sangat ideal untuk penggunaan di lapangan, termasuk di lokasi yang sulit dijangkau.

Kit ini dilengkapi dengan teknologi kalibrasi otomatis dan kompensasi suhu untuk memastikan keakuratan hasil pengukuran. Selain itu, meter ini dapat menyimpan data pengukuran dan memiliki antarmuka yang mudah digunakan, memudahkan pengguna dalam operasional sehari-hari.

Dalam paket ini, Anda akan menemukan meter turbidity, probe, dan semua aksesori yang diperlukan, sehingga siap digunakan segera. Alat ini sangat cocok untuk berbagai aplikasi, termasuk pengujian kualitas air dalam industri, lingkungan, dan laboratorium. Dengan APERA Portable Turbidity Meter Kit, Anda dapat dengan mudah memantau dan menjaga kualitas air dengan efisiensi tinggi.
APERA, Portable water hardness Meter YD300
Rp 1 Rp 1 1.0 IDR
The Apera Instruments YD300 is specially designed for fast and accurate measurement of water hardness (the concentration of calcium ions Ca2+ and magnesium ions Mg2+). The YD300 is equipped with a proprietary601-S water hardness electrode that has been proven to provide the same accuracy as the traditional volumetric EDTA method, but is much more convenient to perform measurements. Unlike the traditional EDTA method, it is not necessary to stir the samples or add reagents during measurements, and the ion concentration of the sample solutions can be measured directly as in pH measurements.

The meter uses an intelligent chip design that supports automatic calibration, data storage (up to 99 groups), and a low battery voltage indicator. The YD300 allows switching between eight common water hardness units, including mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler), mg/L (Ca), ˚fH (France Degree), ˚dH (German Degree), and ˚eH (England Degree).

Application of electrode method to measure hardness, with the same accuracy as EDTA titration method, but much more convenient.
Patented 601-S 3-in-1 water hardness electrode: combines a measuring electrode, a reference electrode and a temperature electrode in one instrument.
Intelligent chip design ensures stable performance potential, fast response time and convenient handling;
Store 99 data; automatic calibration and temperature compensation (ATC), automatic lockout and shutdown.
Portable IP57 waterproof design, equipped as a complete set with a rugged carrying case; suitable for laboratory and field use.

The YD300 is waterproof according to IP57 and is supplied as a complete set. This kit contains the Model 601-S water hardness electrode, water hardness calibration solutions (B1, B2 and B3); matching calibration bottles, water hardness activation solution, a 20 ml test cup, a test cup stand, 2 AA batteries and a quick reference guide in a rugged carrying case. Applications: potable water, wastewater, cooling towers, boilers, piping, aquaculture, pools & spas. Two-year manufacturer’s warranty on the device (6 months on the electrode).

Water Hardness : Measuring range (0 ~ 10) mmol/l; (0 ~ 401) mg/l(Ca);(0 ~ 1000) mg/l(CaCO3); (0 ~ 100)ºfH(French unit);
(0 ~ 561) mg/l(CaO); (0 ~ 56)ºdH(German unit);(0 ~ 20) mmol/l(kettle); (0 ~ 70) ºeH (English unit).
Resolution : 0.01 / 0.1 Water hardness units
Accuracy : ±5% F.S
Temperature compensation : (5 ~ 50°C)(automatic)
Calibration points : 2.00×10-2 mmol/l (B1 calibration solution), 2.00×10-1 mmol/l (B2 calibration solution)
2.00 mmol/l (B3 calibration solution)
Calibration mode : – B1/B2 calibration, suitable for low concentrated water (< 2.00×10-2 mmol/l), e.g. boiler water - B2/B3 calibration, suitable
for general water quality
Temperature : Recommended Operating temp. : 0 ~ 60°C (32 ~ 140°F)
Resolution : 0,1°C
Accuracy : ±0,5°C
Data storage : 99 groups
Storage data : Serial number of measured value, measured value, units, Temperature and calibration method
Power supply : 2 AA batteries (1.5V×2)
Dimensions/Weight : Gauge: (65×120×31) mm/180g; Carrying case: (255×210×50) mm/790g Quality and safety certificate
Ambient temperature : 5 ~ 35°C (41 ~ 95ºF)
Humidity : ≤85%
Housing protection class : IP57, dust and waterproof
APERA, 3M KCl Solution (AgCl Saturation) Volume 250ml/bottle
Rp 1 Rp 1 1.0 IDR
APERA 3M KCl Solution (AgCl Saturation) adalah larutan elektrolit berkualitas tinggi dengan volume 250ml per botol, digunakan untuk mengisi dan menjaga kinerja elektroda pH serta elektroda referensi. Cocok untuk berbagai aplikasi laboratorium, larutan ini memastikan hasil pengukuran yang stabil dan akurat. Ideal untuk pengguna yang membutuhkan solusi elektrolit yang andal dari distributor alat laboratorium PT Ecosains Hayati.